UNIQUE 2 image processing software
Radiography

UNIQUE 2 image processing software

Increase contrast and reduce noise

UNIQUE 2 image processing software increases contrast and reduces noise and artifacts to improve visualization of subtle anatomic details. It delivers superb images through customized parameters and automatic presets that are tuned to the patient type (adult, child or infant, slim or obese) and the requirements of the examination. It harmonizes contrast levels, optimizing images in both heavily exposed and barely exposed areas. With gray scale adjustment, lesions become more conspicuous, even when located in areas that are classically hidden or obscured.

Demonstrated results dose reduction in clinical studies

  1. 54.7%1

    greater contrast

    54.7%1

    greater contrast

    UNIQUE 2 enhances contrast by up to 54.7%1 in pediatric hand images.

  2. 17.3%2

    less noise

    17.3%2

    less noise

    In abdominal areas, phantom measurements showed a noise reduction of up to 17.3%2.

  3. 100%3

    improvement in background consistency

    100%3

    improvement in background consistency

    In pediatric images, UNIQUE 2 improves the consistency of the background area by 100%.3

  4. 16.8%

    improvement in actionable lung nodule detection

    16.8%

    improvement in actionable lung nodule detection

    When combined with Philips Bone Suppression software, UNIQUE 2 improves actionable lung nodule detection by 16.8%.4

Improved diagnostic image quality
UNIQUE 2 offers you extended flexibility to adjust image contrast. In pediatric hand images, UNIQUE 2 enhances contrast by up to 54.7%1. It also features a novel noise reduction algorithm. In abdominal areas, phantom measurements showed a noise reduction of up to 17.3%2. Specific anatomical structures can be selectively enhanced to increase detail visualization and support diagnostic confidence.
Improved Pediatric diagnostic image quality
Fast, easy image adjustments
With a next generation interface and vastly improved image processing functions, image processing parameters can be individually tailored to the personal demands of each radiologist. All adjustments become instantly visible, in excellent quality, on the 2MP monitor. Once created, any custom-made parameter set is automatically applied in daily routine, speeding the exam.
UNIQUE 2 fast easy parameters adjustments
Personalized control
UNIQUE 2 automatically indicates, with a green mark, those areas requiring contrast adjustment. However, you can manipulate this to suit your patient’s need. Using the ‘ranger’ tool, just point to a certain area or structure and place your own mark(s), thereby including it in the medical image processing.
UNIQUE 2 personalized control


UNIQUE 2 integrated with our premium Radiography 7300 C digital radiography system
Fast throughput and diagnostic confidence are not mutually exclusive. The versatile Philips Radiography 7300 C digital radiography system allows you to achieve both. You can comfortably see more patients per day6, reduce time-consuming retakes, and focus more closely on your patients. Smart Workflow, powerful AI-enabled productivity features, and automated examination technologies help assure rapid availability of high-quality digital images for more confident diagnoses.
View product
Radiography 7300 C smart X-ray workflow
Footnotes
  1. Compared to UNIQUE on previous release of Philips DigitalDiagnost – Results of phantom measurements. The effect of noise reduction depends on tissue type.
  2. Compared to UNIQUE on previous release of Philips DigitalDiagnost – Highest values were obtained on pediatric hand images. Results for other examinations vary.
  3. Compared to UNIQUE on previous release of Philips DigitalDiagnost – improves by up to 96.7% within one image, by up to 100% across different images. Results depend on the examination type.
  4. Riverain Technologies' ClearRead Bone Suppression.
  5. Freedman M, et.al. Improved detection of lung nodules with novel software that suppresses the rib and clavicle shadows on chest radiographs. Radiology 2011.
  6. See 15 more patients/day, save 8 hrs. overtime/week, and avoid approx. 28 retakes/week (compared to the previous release of DigitalDiagnost and based on 100 patients per day. Actual results in other cases may vary)
Disclaimer
Results are specific to the institution where they were obtained and may not reflect the results achievable at other institutions. Results in other cases may vary.