Efficia ECG100

Acquisition device

Find similar products

The Efficia ECG100 acquisition device is a cost-effective way to capture, display, and print simultaneous 12-channel ECG waveforms for both inpatient and outpatient care.

Features
kba1

Connecting to care

kba1

Connecting to care

kba1

Connecting to care

kba1
  • kba1
See all features
kba1

Connecting to care

kba1

Connecting to care

kba1

Connecting to care

kba1

Low Cost ECG Connecting to care

 

The Efficia ECG100 provides 4 hours of non-stop usage with an easy-to-use, intuitive interface in a small (<300 grams), portable design. Ultra-portable and built to work with app‑enabled smartphones and tablets for Android™, ECG100 users can view 12-channel ECGs directly on their mobile devices. The specially-designed app offers an intuitive user interface with simple workflow, display, storage, and seamless sharing of ECG reports. The Low cost ECG functions without any infrastructure WiFi.

A Patient Being Monitored with Efficia ECG 100
Efficia ECG 100 - Affordable Patient Monitoring Solutions

Enhancing patient care, affordably

 

Efficia ECG100 offers field-proven Philips technology with a low cost of ownership, so you can share health information with cardiologists and specialists, anywhere. This diagnostic-quality ECG acquisition device is designed for clinics, nursing homes, hospitals, and other healthcare centers, allowing technicians and clinicians to enhance patient care.

Efficia ECG Unique advantages

 

Efficia ECG100 sends wireless reports to a computer, off-site health expert or deliver fast ECG reporting to a printer with A4 paper to print in grayscale or color. The Efficia ECG100 also allows users to store ECG PDF reports easily with large storage capacity (1,000 ECGs per 1GB) on the device. ECG relays waveforms to an app-enabled Android smartphone or tablet and can reference past ECGs for further evaluation and follow-up care. Accurate readings are enabled by lead map, lead disconnection, and noise level indicators.

ECG Readouts Being Studied

Schematic ECG Workflow overview

Schematic - Low Cost ECG Workflow
circle number 1

Acquisition box captures high-quality ECGs from the patient

circle number 2

These ECGs are wirelessly transmitted to an Android based tablet or phone

circle number 3

From the Android based device, ECGs can be transmitted to a printer, PC or to a Specialist

Customer story

quotation mark

This eliminates the need to photo copy ECG for known cardiac patients (as thermal prints fade over just couple of weeks)."

 

Dr. Ranjan Shetty, Unit Head, Cardiology - KMC, Manipal

Documents

Specifications

Battery
Battery
Type
  • Lithium-ion rechargeable battery
Capacity
  • 3.7V typical with 1.9AH battery capacity
Life cycle
  • At least 300 charging cycles
ECG acquisition device
ECG acquisition device
Patient module
  • Separate ECG acquisition device
Dimensions
  • &lt;lt/> 150 mm (L) x 90 mm (W) x 30 mm (H)
Weight
  • &lt;lt/> 0.4 kg (without ECG cable)
Power adapter
  • Input voltage: 100 to 240VAC Input current: Maximum 0.15A @ 240VAC Input frequency: 47 to 63Hz Output voltage: 5V ± 5% Maximum output current : 2A
Operating conditions
  • Temperature 10 °C to 40 °C (50 °F to 104 °F) Humidity 10% to 90% relative humidity (non-condensing)
Display/data screen
Display/data screen
Touch screen
  • Resistive/capacitive touch screen on tablet/mobile phone
Display channels
  • 12
Keyboard
  • Touch keyboard on tablet/mobile phone
Displayed patient data
  • Patient name and age, heart rate, waveforms
Other displayed data
  • Acquisition device battery indicator, lead label, speed, gain, filter settings, warning messages, info messages, prompts, 12 lead standard display
ECG measurements
ECG measurements
Standard global measurements
  • Yes
Connectivity
Connectivity
Soft AP mode WiFi connectivity
  • From acquisition device to application
Storage
Storage
Number of ECGs stored
  • Storage depends on SD card capacity and internal memory of the tablet/mobile phone; 1,000 ECGs can be stored on 1 GB
ECG acquisition details
ECG acquisition details
Number of channels
  • 12
Acquisition mode
  • 10 seconds simultaneous data
ECG report format
  • PDF
ECG report output
  • 6x2, 3x4, 3x4 + 1R, 1x1, lead groups
Pace pulse detection
  • Yes
Raw data acquisition on analog front end
  • 1,000 samples per second
Sampling rate
  • 500 samples per lead
Auto frequency response
  • 0.05-150Hz, 0.15-150Hz, 0.5-150Hz, 0.05-100Hz, 0.15-100Hz, 0.5-100Hz, 0.05-40Hz, 0.15-40Hz, 0.5-40Hz
Key features
Key features
Simultaneous 12-lead ECG from 10 electrodes
  • Yes
Defibrillator protection
  • Yes
Leads off detection
  • Yes
AC noise removal
  • Yes
Wireless printing of PDF ECG report
  • No
LED indication on acquisition device for battery, WiFi, power, and ready to acquire ECG
  • Yes
Device Requirements
Device Requirements
Display
  • Uses off-the-shelf Android-based tablet/mobile phone
Display size
  • Minimum 4.2 inch screen size
Display resolution
  • Minimum 800 x 480 pixel
Memory
  • Minimum 512 MB configured RAM and 1 GB flash memory
Environmental storage conditions
Environmental storage conditions
Temperature
  • -20 °C to 50 °C (-4 °F to 122 °F)
Humidity
  • 10% to 90% relative humidity (non-condensing)
Classifications
Classifications
IEC safety classification
  • Class II Equipment
Applied part
  • Defibrillation proof type CF applied part
IP rating
  • IPX1
ECG Cable
ECG Cable
10-lead wire single connector lead set
  • Yes
IEC
  • Yes
Banana plug type connectors
  • Yes
Standards compliance
Standards compliance
IEC 60601-1: Ed 3.1 2012
  • General requirements for basic safety and essential performance
IEC 60601-2-25, Ed 2.0 2011
  • Particular requirements for the basic safety and essential performance of electrocardiographs
IEC 60601-1-2: Ed 3.0 2007
  • Electromagnetic compatibility requirements and tests
Battery
Battery
Type
  • Lithium-ion rechargeable battery
Capacity
  • 3.7V typical with 1.9AH battery capacity
ECG acquisition device
ECG acquisition device
Patient module
  • Separate ECG acquisition device
Dimensions
  • &lt;lt/> 150 mm (L) x 90 mm (W) x 30 mm (H)
See all specifications
Battery
Battery
Type
  • Lithium-ion rechargeable battery
Capacity
  • 3.7V typical with 1.9AH battery capacity
Life cycle
  • At least 300 charging cycles
ECG acquisition device
ECG acquisition device
Patient module
  • Separate ECG acquisition device
Dimensions
  • &lt;lt/> 150 mm (L) x 90 mm (W) x 30 mm (H)
Weight
  • &lt;lt/> 0.4 kg (without ECG cable)
Power adapter
  • Input voltage: 100 to 240VAC Input current: Maximum 0.15A @ 240VAC Input frequency: 47 to 63Hz Output voltage: 5V ± 5% Maximum output current : 2A
Operating conditions
  • Temperature 10 °C to 40 °C (50 °F to 104 °F) Humidity 10% to 90% relative humidity (non-condensing)
Display/data screen
Display/data screen
Touch screen
  • Resistive/capacitive touch screen on tablet/mobile phone
Display channels
  • 12
Keyboard
  • Touch keyboard on tablet/mobile phone
Displayed patient data
  • Patient name and age, heart rate, waveforms
Other displayed data
  • Acquisition device battery indicator, lead label, speed, gain, filter settings, warning messages, info messages, prompts, 12 lead standard display
ECG measurements
ECG measurements
Standard global measurements
  • Yes
Connectivity
Connectivity
Soft AP mode WiFi connectivity
  • From acquisition device to application
Storage
Storage
Number of ECGs stored
  • Storage depends on SD card capacity and internal memory of the tablet/mobile phone; 1,000 ECGs can be stored on 1 GB
ECG acquisition details
ECG acquisition details
Number of channels
  • 12
Acquisition mode
  • 10 seconds simultaneous data
ECG report format
  • PDF
ECG report output
  • 6x2, 3x4, 3x4 + 1R, 1x1, lead groups
Pace pulse detection
  • Yes
Raw data acquisition on analog front end
  • 1,000 samples per second
Sampling rate
  • 500 samples per lead
Auto frequency response
  • 0.05-150Hz, 0.15-150Hz, 0.5-150Hz, 0.05-100Hz, 0.15-100Hz, 0.5-100Hz, 0.05-40Hz, 0.15-40Hz, 0.5-40Hz
Key features
Key features
Simultaneous 12-lead ECG from 10 electrodes
  • Yes
Defibrillator protection
  • Yes
Leads off detection
  • Yes
AC noise removal
  • Yes
Wireless printing of PDF ECG report
  • No
LED indication on acquisition device for battery, WiFi, power, and ready to acquire ECG
  • Yes
Device Requirements
Device Requirements
Display
  • Uses off-the-shelf Android-based tablet/mobile phone
Display size
  • Minimum 4.2 inch screen size
Display resolution
  • Minimum 800 x 480 pixel
Memory
  • Minimum 512 MB configured RAM and 1 GB flash memory
Environmental storage conditions
Environmental storage conditions
Temperature
  • -20 °C to 50 °C (-4 °F to 122 °F)
Humidity
  • 10% to 90% relative humidity (non-condensing)
Classifications
Classifications
IEC safety classification
  • Class II Equipment
Applied part
  • Defibrillation proof type CF applied part
IP rating
  • IPX1
ECG Cable
ECG Cable
10-lead wire single connector lead set
  • Yes
IEC
  • Yes
Banana plug type connectors
  • Yes
Standards compliance
Standards compliance
IEC 60601-1: Ed 3.1 2012
  • General requirements for basic safety and essential performance
IEC 60601-2-25, Ed 2.0 2011
  • Particular requirements for the basic safety and essential performance of electrocardiographs
IEC 60601-1-2: Ed 3.0 2007
  • Electromagnetic compatibility requirements and tests
  • The Efficia ECG100 is not available in all geographies; please check with your Philips representative for more information.

You are about to visit a Philips global content page

Continue

You are about to visit a Philips global content page

Continue

Our site can best be viewed with the latest version of Microsoft Edge, Google Chrome or Firefox.