Why cookies? Simply because they are used to help the website function, to improve your browser experience, to integrate with social media and to show relevant advertisements tailored to your interests. Click 'I understand' to accept cookies and go directly to the site or click 'Change settings' to change your cookie preferences. Click here

Close

Home

Therapy Systems

MRCAT Prostate + Auto-Contouring

MR-RT clinical application

Find similar products

As a plug-in clinical application to Ingenia MR-RT, MRCAT Prostate + Auto-Contouring provides attenuation maps and automated, MR-based contours of prostate and organs at risk in as little as 20 minutes – all in a repeatable ‘one-click’ workflow.

Request contact

Features

Drive speed, accuracy and consistency

Drive speed, accuracy and consistency

Because MRCAT Prostate requires input from MR images only, it reduces the organization and coordination of scans, eliminates the effort involved in MR-CT registration, and saves the patient from undergoing multiple procedures. Moreover, Auto-Contouring automates standard, labor-intensive and repetitive tasks, while at the same time reducing variability and errors caused by manual steps. This improves consistency and reproducibility - for more confidence in the planning process.

Fast, consistent imaging protocol

Fast, consistent imaging protocol

A dedicated, standardized imaging protocol includes a T1W mDIXON XD and a T2W TSE scan as source data for the generation of MRCAT (MR for Calculating ATtenuation) density maps and MR-based Auto-Contouring. Compressed SENSE acceleration keeps the total scan time short, which promotes patient comfort by minimizing time in the scanner and helps to boost productivity.

Automatic generation of synthetic CT images

Automatic generation of synthetic CT images

MRCAT Prostate automatically generates attenuation maps using the high-resolution mDIXON scan as source. Smart, validated algorithms enable automatic tissue segmentation and assignment of Hounsfield Units to deliver MRCAT images with CT-like density information for dose calculations - directly on the MR console.

Accuracy in dose planning

Accuracy in dose planning

The MRCAT Prostate scanning protocol and generation algorithms have been designed with the strict accuracy requirements of RT in mind. MRCAT Prostate images have high geometric accuracy* and validation studies have shown that MRCAT-based dose plans are robust and equivalent** to CT-based plans promoting confidence in dose planning.

Create accurate*** contours with little to no user interaction

Create accurate*** contours with little to no user interaction

MR-based Auto-Contouring automatically creates contours of prostate and OARs, reducing repetitive tasks and time spent, compared to manual methods. It uses dedicated MR imaging data based on the 3D T2W TSE and T1W mDIXON XD sequences and model-based adaptive algorithms. Auto-Contouring delineation of prostate and OARs has been found to be accurate (average distance < 1.5mm)*** in at least 70% of contours evaluated****. This significantly reduces the need for manual contouring or manual adaptations, while increasing consistency.

MRI as primary image set in treatment planning

MRI as primary image set in treatment planning

The MRCAT images generated on the MR console conform to the DICOM standard (modality CT) and hence can be exported to treatment planning systems (TPS) as the primary image dataset. Together with the generated contours (RTSTRUCT) and the ability to generate MRCAT-based digitally reconstructed radiographs (DRRs), you can replace your traditional CT-based workflow with an MRI-only radiotherapy workflow from imaging and planning to position verification.

Put Philips MR-only radiotherapy to work today

Put Philips MR-only radiotherapy to work today

To successfully bring MR-only radiotherapy into your clinical routine, we recognize that you must look beyond the imaging itself and address important steps such as patient marking, position verification, and quality assurance. We are prepared to support you throughout this process. To this end, we offer dedicated workflow descriptions, best practice sharing and tailored training support, designed to provide assistance as you adopt this new treatment paradigm.
MRCAT Prostate + Auto-Contouring | Philips

You are about to visit a Philips global content page

Continue

You are about to visit a Philips global content page

Continue

Our site can best be viewed with the latest version of Microsoft Edge, Google Chrome or Firefox.