Efficia ECG100 Acquisition device

Efficia ECG100

Acquisition device

Product number:

NOCTN293

The Efficia ECG100 acquisition device is a cost-effective way to capture, display, and print simultaneous 12-channel ECG waveforms for both inpatient and outpatient care.

The Efficia ECG100 acquisition device is a cost-effective way to capture, display, and print simultaneous 12-channel ECG waveforms for both inpatient and outpatient care.

Low Cost ECG Connecting to care

 

The Efficia ECG100 provides 4 hours of non-stop usage with an easy-to-use, intuitive interface in a small (<300 grams), portable design. Ultra-portable and built to work with app‑enabled smartphones and tablets for Android™, ECG100 users can view 12-channel ECGs directly on their mobile devices. The specially-designed app offers an intuitive user interface with simple workflow, display, storage, and seamless sharing of ECG reports. The Low cost ECG functions without any infrastructure WiFi.

Enhancing patient care, affordably

 

Efficia ECG100 offers field-proven Philips technology with a low cost of ownership, so you can share health information with cardiologists and specialists, anywhere. This diagnostic-quality ECG acquisition device is designed for clinics, nursing homes, hospitals, and other healthcare centers, allowing technicians and clinicians to enhance patient care.

Efficia ECG Unique advantages

 

Efficia ECG100 sends wireless reports to a computer, off-site health expert or deliver fast ECG reporting to a printer with A4 paper to print in grayscale or color. The Efficia ECG100 also allows users to store ECG PDF reports easily with large storage capacity (1,000 ECGs per 1GB) on the device. ECG relays waveforms to an app-enabled Android smartphone or tablet and can reference past ECGs for further evaluation and follow-up care. Accurate readings are enabled by lead map, lead disconnection, and noise level indicators.

Schematic ECG Workflow overview

Acquisition box captures high-quality ECGs from the patient
These ECGs are wirelessly transmitted to an Android based tablet or phone
From the Android based device, ECGs can be transmitted to a printer, PC or to a Specialist

Specifications Show all

ECG acquisition device
Patient module
Separate ECG acquisition device
Dimensions
<lt/> 150 mm (L) x 90 mm (W) x 30 mm (H)
Weight
<lt/> 0.4 kg (without ECG cable)
Power adapter
Input voltage: 100 to 240VAC Input current: Maximum 0.15A @ 240VAC Input frequency: 47 to 63Hz Output voltage: 5V ± 5% Maximum output current : 2A
Operating conditions
Temperature 10 °C to 40 °C (50 °F to 104 °F) Humidity 10% to 90% relative humidity (non-condensing)
Battery
Type
Lithium-ion rechargeable battery
Capacity
3.7V typical with 1.9AH battery capacity
Life cycle
At least 300 charging cycles
Display/data screen
Touch screen
Resistive/capacitive touch screen on tablet/mobile phone
Display channels
12
Keyboard
Touch keyboard on tablet/mobile phone
Displayed patient data
Patient name and age, heart rate, waveforms
Other displayed data
Acquisition device battery indicator, lead label, speed, gain, filter settings, warning messages, info messages, prompts, 12 lead standard display
ECG measurements
Standard global measurements
Yes
Connectivity
Soft AP mode WiFi connectivity
From acquisition device to application
Storage
Number of ECGs stored
Storage depends on SD card capacity and internal memory of the tablet/mobile phone; 1,000 ECGs can be stored on 1 GB
ECG acquisition details
Number of channels
12
Acquisition mode
10 seconds simultaneous data
ECG report format
PDF
ECG report output
6x2, 3x4, 3x4 + 1R, 1x1, lead groups
Pace pulse detection
Yes
Raw data acquisition on analog front end
1,000 samples per second
Sampling rate
500 samples per lead
Auto frequency response
0.05-150Hz, 0.15-150Hz, 0.5-150Hz, 0.05-100Hz, 0.15-100Hz, 0.5-100Hz, 0.05-40Hz, 0.15-40Hz, 0.5-40Hz
Key features
Simultaneous 12-lead ECG from 10 electrodes
Yes
Defibrillator protection
Yes
Leads off detection
Yes
AC noise removal
Yes
Wireless printing of PDF ECG report
No
LED indication on acquisition device for battery, WiFi, power, and ready to acquire ECG
Yes
Device Requirements
Display
Uses off-the-shelf Android-based tablet/mobile phone
Display size
Minimum 4.2 inch screen size
Display resolution
Minimum 800 x 480 pixel
Memory
Minimum 512 MB configured RAM and 1 GB flash memory
Environmental storage conditions
Temperature
-20 °C to 50 °C (-4 °F to 122 °F)
Humidity
10% to 90% relative humidity (non-condensing)
Classifications
IEC safety classification
Class II Equipment
Applied part
Defibrillation proof type CF applied part
IP rating
IPX1
ECG Cable
10-lead wire single connector lead set
Yes
IEC
Yes
Banana plug type connectors
Yes
Standards compliance
IEC 60601-1: Ed 3.1 2012
General requirements for basic safety and essential performance
IEC 60601-2-25, Ed 2.0 2011
Particular requirements for the basic safety and essential performance of electrocardiographs
IEC 60601-1-2: Ed 3.0 2007
Electromagnetic compatibility requirements and tests

Customer story

This eliminates the need to photo copy ECG for known cardiac patients (as thermal prints fade over just couple of weeks)."

 

Dr. Ranjan Shetty, Unit Head, Cardiology - KMC, Manipal